• Sourcing Solutions
  • Services & Membership
  • Help & Community

Quick Details

  • Type: Drains
  • Place of Origin: Japan
  • Brand Name: C Trap
  • Model Number: C Trap-2971
  • Material: Plastic
  • Surface Treatment: Polished
  • Style: Push Down Pop-Up
  • Application: Floor

Packaging & Delivery

Packaging Details Securely packaged in cardboard with buffering material
Delivery Time Shipped within 3 to 7 days after payment is confirmed.

High quality and Reliable generator prices distributor wanted at reasonable prices ,small lot order available           

 

• Our special float ball prevents back flow of contaminated air even if seal water dries up

• Excellent anti-odor anti-insect effects

• Internal parts are easily removed for inspection/cleaning

URL  http:www.kondoh-frp.co.jp

 

Product Description

 

This will contribute greatly to air-conditioning drains.

 

Many uses for our compact trap
In small air conditioners for individual air conditioning, measures are often not taken to prevent

back flow of air from water drainage pipes. By attaching a "C Trap" to each air conditioner,

back flow of air is prevented, thereby preventing air pollution.

It can also be used for a variety of applications such as drainage of automatic air vent valves

or as a trap for draining expanded water in electric water heater tanks.

 

 

 

 

 

 

 

Packaging & Shipping

 

 

 

ContentQuantity
Main body1
Connector2
Instruction manual1

 

 

 

 

Product nameContained quantity (Pcs)Dimensions (mm)Weight (kg)
C TRAP 25A20500×375×2357
C TRAP 30A20550×375×2358
C TRAP 40A20675×445×26511
C TRAP 50A20775×525×30516

 

 

Installations

 

• Houses of Parliament Japan
• Tokyo International Airport Japan
• Great Hall of the People China
• Osaka Castle Japan


 

 

Company Information

 

 

 

Since our establishment in 1969, we have developed unique, one-of-a-kind products.

Our A-traps and drain traps for air-conditioners have been best-sellers for over 30 years and

boast total sales of over 200,000 units.

Our C-traps and drain traps for small air conditioning units,

for which international patents have been acquired,

have been widely recognized for their excellent performance since their introduction in 2004,

and have been used in numerous major government facilities such as the Japanese Parliament

Building and China's Great Hall of the People.

 

 

 

 

 

Grease trap: our product solves various problems inherent to conventional grease traps,

and simplifies maintenance.


Kitchen drainage exclusion facilities: we can provide an environmentally clean, energy saving,

low cost treatment solution for excluding animal and vegetable oil from waste water.

 

Air-conditioning drain trap: the float ball design has an odor-preventing effect,

even when seal water dries up.

 

Expansion tank: an expansion tank that takes advantage of the excellent features of FRP.

 

Storage tank: loose lining method using heat-resistant FRP

 

FRP lining construction: water tanks and hot water tanks are revived with the excellent

properties of FRP.

 

 

 

Patent numbers

 

Japan: No.4614729
US: No.US7,976,701 B2
China: No.ZL 2005 8 0001674.2
Hong Kong: No.HK1118084

odors and insects from entering the room even when there is no sealing water. And as our 30 years of experience shows, all of our products have  excellent  durability,  easy  maintenance, inspection, and cleaning, and look great.Odor Prevention The use  of a  check  valve (Special  floatball)  and floating  valve  prevents backflow and bad odors.FRP does not rust. Therefore, you don’t need to worry about corrosion  on  the  inside  or outside.  Also,  condensation does not form easily on it. Main Unit Materials are FRP Due to the lightweight and floor  installation  type construction,  it  is  easy  to carry in, set, and install.Work efficiency Easy maintenance, inspec tion  and  cleaning  through the top  cap, trap cap,  and float valve chest cap.Maintenance,Inspection, Cleaning A Trap types and selection flow There are basically 2 types of A Trap, the <Suction Type> and < Pressurized Type>, and  you can select the  type required according to the type of air conditioner (negative pressure/positive pressure) used. In particular, if you need to implement counter measures against condensation, we recommend you select the <heat insulation type>, which is the A trap unit that has been fitted with insulating material. 3 different sizes of connecting diameter are available. There are further 3 additional custom made products available.Selection Conditions A Trap Variations Types of A Trap Suction Type <S Type> Suction Insulated Type <SW Type> Pressurized Type <P Type> Pressurized Insulated Type <PW Type> Air Conditioner Type Condensation Counter Measures Negative Pressure Positive Pressure Flow Inlet/Flow Outlet Socket Size Custom Products Not Required Required Not Required Required 3 Types of Connecting Pipe Size Transparent Cap Specifications Acrylic cap enabling you to see inside Heat Resistance Specifications (Max 80°C) Support for high temperature drainage water by changing the trap material Water Drainage Pipe Connector Specifications The main unit side is equipped with a connector for a water drainage pipe SUS Specifications Main unit constructed of stainless steel 32A 40A 50A This diagram is an example of installation when the main unit  side is equipped with a chilled water coil  drainage pipe/hot water coil drainage pipe connector (order made) The  two  checking  functions  of  the  non return  valve (special  floatball)    and  float  valve  operate  to  prevent odors  and  insects  from  entering  the  room,  even  if  the sealing water has evaporated.Positive pressure in the air conditioner up to an  equivalent  of  1,470pa  (150mmAq)  is supported, preventing blow back. *When installing the suction type <S Type>, find the h dimension from the performance curve that corresponds to the internal static pressure of the air conditioner, and install it at a height greater than h.*1) When finding the h dimension for the suction insulated type <SW>, add 10mm to the value obtained from the graph. *2)When  starting  operation  of  the  air  conditioner, always fill the main unit to the flow outlet side section top with water. Filling with water causes a water seal to form, preventing air from flowing out.Example uses Around the air conditioner drain trap Pipe Arrangement View Construction/Performance Suction Type <S Type / SW Type>Pressurized Type<P Type / PW Type>Air Conditioner Air Conditioner Air conditioner base Mortar Concrete slab Hot water coil drainage pipe Drain drainage pipe Water drainage pipe connector Chilled water coil drainage pipe Trap

Non return valve Float valve (Special floatball)<Plan View><Elevated View>Performance Curve (For suction type <S Type>) *1)Relationship between negative pressure from various water quantities and h(h: Height from bottom of main unit to air conditioner drain pan)*When installing the suction type <S Type>, find the h dimension from the performance curve that corresponds to the internal static pressure of the air conditioner, and install it at a height greater than h.*1) When finding the h dimension for the suction insulated type <SW>, add 10mm to the value obtained from the graph.Positive pressure in the air conditioner up to an  equivalent  of  1,470pa  (150mmAq)  is supported, preventing blow back. When  starting  operation  of  the  air  conditioner, always fill the main unit to the flow outlet side section top with water. Filling with water causes a water seal to form, preventing air from flowing out. A Trap External Dimensions Cautions for Installation and Handling of “A Trap”[Law for Maintenance of Sanitation in Buildings (Common name: Building Sanitation Law or Building Maintenance Law)] (Ministry of Health, Labour and Welfare)Points of Amendments and Counter Measures Both  the A  Trap  and  C  trap  are  designed  to  effectively  prevent  infestations  of  mice, insects, and pathogens, bad odors, and the transmission of air borne infections via air conditioner drainage pipes, and are constructed for easy maintenance. The  development  and manufacture  of  all  our products conform  to  Japanese  laws, ordinances, and regulations.The importance of  maintaining a sanitary  environment for the drainage system  of  air  conditioners  was  strengthened  in  the  2002  Ministry  of Health, Labour and Welfare reforms of the “Law for Maintenance of Sani tation in  Buildings  (Common name: Building Sanitation Law or Building Maintenance Law)”. *For details, see the “Legal Guide” on page 6.Due to obligations outlined in the 2003 amendments to the Building Stan dards Act, in the background of the development of high performance air filters, awareness of the importance of the air quality is being improved.We believe the installation of the drain trap for air conditioning units is just one of continuing efforts to achieve better air quality.Floatball Drain Trap Series for Air Conditioning UnitsIn addition to the outstanding air backflow prevention performance of the logical floatball system, the drain traps are both easy to install, and easy to inspect and clean.The drainage pipes on an air conditioning unit are connected to the draining basin in order to drain condensation that occurs when running in cooling mode. However, dirty air in the atmosphere also flows  through  the  drainage  pipes  from  the breather inlet.  In order to protect the quality of air inside the room, it is important to prevent odors and  insects  from  entering  the  room  from  the drainage pipe. Drain  trap  for  medium/large  sized  air conditioners.  The  dual  check  valve function  is  effective  in  preventing  the backflow of bad odors even during high static pressure operation.: Medium/large sized air conditioners such as air handling units : Machine room Floor installation 32A, 40A, 50AMain installations Main installation location Installation method Connection diameters Drain  trap  for  small  air  conditioners. Due  to  their  small  size,  they  can  be installed  in  confined  areas  above  the ceiling etc. Small  air  conditioners  such  as  fan  coil  units,  room units for building multiple air conditioners, and floor installed  package  air  conditioners  (Internal  static  pressure: 0~ 500pa)  Above the ceiling, inside the pipe shaft etc Incorporated into plumbing Main installationsMain installation location Installation method Connection diameters Dirty  air  is  also  transported  by the drainage pipes.Movement of air due to the differences in operating conditions of the air conditioners Movement of air due to the differences in operating conditions of the air conditioners Movement of air due to imbalance of air supply Movement of air due to imbalance of air supply Movement of air due to drainage water and flow of air in pipes Movement of air due to ventilator pressure of large air conditioner Non fecal wastewater container Drainage water from air conditioners as a rule cannot  be  discharged  into  the  street  inlet. (Sewerage Law)Floatball air backflow prevention valve is extremely effective, even when the sealing water has evaporated Drain  trap  for  medium/large  sized  air conditioners.  The  dual  check  valve function  is  effective  in  preventing  the backflow of bad odors even during high static pressure operation. Medium/large sized air conditioners such as air handling units Machine room Floor installation Main installation location Installation method Connection diameters Drain  trap  for  small  air  conditioners. Due  to  their  small  size,  they  can  be installed  in  confined  areas  above  the ceiling etc. Small  air  conditioners  such  as  fan  coil  units,  room units for building multiple air conditioners, and floor installed  package  air  conditioners  (Internal  static  pressure: 0~ 500pa) Above the ceiling, inside the pipe shaft etc Incorporated into plumbing Main installations Main installation location Installation method Connection diameters< International Patent Pending >When an A trap is installed in the drainage pipe of a large air conditionerBackflow of air/ingress of  insects into the air conditioner is prevented When the C trap is installed in the drainage pipe of a small air conditioner Prevents the backflow of air/ingress of insects into the air conditioner Floatball type drain trap for medium/large air conditioners For clean air“A Trap” is a box type floor installation drain trap for air conditioners. Designed logically with dual check  valves, A Trap is effective  in preventing

Floatball type drain trap for small air conditioners Multi-use compact trap At present, there are many small type individual room air condi-tioners that are not equipped to prevent the backflow of air from the drainage pipes. You can prevent the backflow of air and therefore the inclusion of dirty air by installing the “C Trap” to each individual air conditioner. Additionally, you can also use the  C Trap  for  many  other  purposes,  such  as  a  trap  for  the drainage water from automatic air extraction valves or expan-sion tanks for electric water heaters.Special  floatball  effectively prevents the backflow of dirty air even if the sealing water evapo-rates Outstanding odor prevention and insect prevention Super-compact  design  makes  it perfect  as  a  drainage  trap  for small air conditioners Internal  parts  can  be  installed and  removed  easily,  making inspections  and  cleaning  easy too Easy  inspection  of  concealed sections thanks to reflective tape Horizontal Installation Type Main Applications Drain trap for air conditioners Fan coil units Building multiple air conditioners (indoor equipment)Small floor installed package air conditioners (indoor equipment) Other small air conditioners Expansion tank drainage water trap for electric water heaters, “Ecocute” etc. Drainage water trap for latent heat collection gas water heaters Drainage water trap for refrigerators and chilled showcases Drainage water trap for ice machine Drainage water trap for automatic air release valve You do not need to install a U trap or other such device at the end of the drainage pipe.Cautions for installation and handling of C Trap Make sure you fully read through the instruction manual included with the product before installation, and make sure you use the product correctly. When connecting this product, make sure that a double-trap is not formed. For medium and large sized air conditioners, use the A Trap. Be careful not to confuse similar products or products with similar names.Example of connection to a small air conditioner drain pipe The difference H is required depending on the internal static pressure of the connected air conditioner. H(mm)=X(Pa)÷9.8(Example) When the internal static pressure: -294Pa 294(Pa)÷9.8=30(mmAq) →Therefore, the difference H must be greater than 30mm.Scope of Use : Internal static  pressure: 0~-500pa Connection method for connection to drain up mechanism air conditioner Correct Connection Method When connecting the C Trap to a drain up mechanism pipe, connect to the horizontal pipe  when  the  reversed  U  shaped  pipes are pointing downwards.

 

 

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
Japan
Supplier Assessments:
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $
Learn More